Программа cap 505 инструкция

Download or browse on-line these Operation User’s Manual.

Summary of Contents:

[Page 1] ABB CAP 505

1MRS751982-MUM Issued: 30.11.2000 Version: A Program revision: 4.0.3 We reserve the right to change data without prior notice. Protocol Editing Tool User’s Guide CAP 505 Notice 1 The information in this document is subject to change without notic.

[Page 2] ABB CAP 505

ABB Automation LIB 500 manuals LIB 510 manuals SMS 510 manuals CAP 505 manuals Common manual for LIB, CAP and SMS LIB 500 Configuration Manual 1MRS751880-MEN LIB 500 Operator’s Manual 1MRS751885-MUM LIB 510 Configuration 1MRS751886-MEN LIB 510 MV .

[Page 3] ABB CAP 505

ABB Automation 1 2 3 1 Introduction 2 Using the POD tool 3 POD tool functionality CAP 505 Protocol Editing Tool User’s Guide 1MRS751982-MUM .

[Page 4] ABB CAP 505

[Page 5] ABB CAP 505

ABB Automation ContentsUser’s Guide Contents: 1. Introduction . 1 1.1. General . 1 1.

[Page 6] ABB CAP 505

ABB cap505 연결방법

ABB Automation 1MRS751982-MUM Protocol Editing Tool Contents User’s Guide 3.5. Changing active function blocks . 20 3.6. Communications .

[Page 7] ABB CAP 505

CAP 505 ABB Automation 1 User’s Guide 1. Introduction 1 1. Introduction Using this manual You should read this manual when you start working with the Protocol Editing Tool (in this manual called POD tool) for the first time. The manual describes .

[Page 8] ABB CAP 505

[Page 9] ABB CAP 505

CAP 505 ABB Automation 3 User’s Guide 2. Using the Protocol Edit- ing Tool 2 2. Using the Protocol Editing Tool 2.1. General This chapter describes the different menus and functions in the Protocol Editing Tool and how to use these. 2.2. Protoc.

Читайте также:
Установить программу для просмотра видео

[Page 10] ABB CAP 505

4 ABB Automation 1MRS751982-MUM Protocol Editing Tool CAP 505 2. Using the Protocol Edit- ing Tool User’s Guide When the POD tool is started a dialog pops up on the screen and the user is asked if there is a connection to the device or not. See Fi.

[Page 11] ABB CAP 505

1MRS751982-MUM CAP 505 ABB Automation 5 Protocol Editing Tool User’s Guide 2. Using the Protocol Edit- ing Tool 2 2.3.2. File menu The following figure shows the POD tool file menu. The different menu functions are explained below. )LJ�.

[Page 12] ABB CAP 505

6 ABB Automation 1MRS751982-MUM Protocol Editing Tool CAP 505 2. Using the Protocol Edit- ing Tool User’s Guide 2.3.2.3. Export This option allows you to export a complete protocol table or only the selected cells in it. It is saved as a text file.

[Page 13] ABB CAP 505

1MRS751982-MUM CAP 505 ABB Automation 7 Protocol Editing Tool User’s Guide 2. Using the Protocol Edit- ing Tool 2 2.3.3. Edit menu The following figure shows the components of the Edit menu of the POD tool. The greyed functions are disabled when .

[Page 14] ABB CAP 505

8 ABB Automation 1MRS751982-MUM Protocol Editing Tool CAP 505 2. Using the Protocol Edit- ing Tool User’s Guide )LJ 7KHYLHZPHQX With the functions in this menu you define which signals you want to view in the PO.

ABB CAP505-REF610 SETTING AND TESTING

[Page 15] ABB CAP 505

1MRS751982-MUM CAP 505 ABB Automation 9 Protocol Editing Tool User’s Guide 2. Using the Protocol Edit- ing Tool 2 You can also choose the upload button from the toolbar (see the figure below). 2.3.5.2. Download Downloading means that you transfer .

[Page 16] ABB CAP 505

10 ABB Automation 1MRS751982-MUM Protocol Editing Tool CAP 505 2. Using the Protocol Edit- ing Tool User’s Guide )LJ $ERXW32’7RROGLDORJ The dialog box About POD Tool contains information on current versio.

[Page 17] ABB CAP 505

CAP 505 ABB Automation 11 User’s Guide 3. Protocol Editing Tool functionality 3 3. Protocol Editing Tool functionality This chapter explains how to use the Protocol Editing tool (POD tool). 3.1. Main dialog A typical view of the POD tool main dia.

[Page 18] ABB CAP 505

12 ABB Automation 1MRS751982-MUM Protocol Editing Tool CAP 505 3. Protocol Editing Tool functionality User’s Guide The statusbar contains five fields: 1. Current path selected in the navigator tree 2. Status field of the consistency between the o.

Читайте также:
Какой программой можно узнать все о компьютере

[Page 19] ABB CAP 505

1MRS751982-MUM CAP 505 ABB Automation 13 Protocol Editing Tool User’s Guide 3. Protocol Editing Tool functionality 3 3.1.1.1. Using the navigator tree The navigator tree is built according to the sorting mode that is in use. No sorting If the cu.

[Page 20] ABB CAP 505

14 ABB Automation 1MRS751982-MUM Protocol Editing Tool CAP 505 3. Protocol Editing Tool functionality User’s Guide 3.1.2. Customizing tables view The user can choose which columns should be visible in each table. This is defined in the “Custom.

[Page 21] ABB CAP 505

1MRS751982-MUM CAP 505 ABB Automation 15 Protocol Editing Tool User’s Guide 3. Protocol Editing Tool functionality 3 the menu File -> Open.. command, or the “Open” toolbar button. When you choose “Open” the following dialog appears on.

[Page 22] ABB CAP 505

16 ABB Automation 1MRS751982-MUM Protocol Editing Tool CAP 505 3. Protocol Editing Tool functionality User’s Guide checksum is the same as the value read from the channel corresponding to the protocol number of the configuration. Consistent conf.

[Page 23] ABB CAP 505

1MRS751982-MUM CAP 505 ABB Automation 17 Protocol Editing Tool User’s Guide 3. Protocol Editing Tool functionality 3 Which one of the methods is used depends on the column type, column display mode and “Fast edit” mode status. When some cell.

[Page 24] ABB CAP 505

18 ABB Automation 1MRS751982-MUM Protocol Editing Tool CAP 505 3. Protocol Editing Tool functionality User’s Guide  Choose, from the pop-up dialog, the column display mode that you want and click OK. )LJ 7KHB TBM6PCR-LI

  • BlueSpot 07966
  • Skil 3300MS
  • Milwaukee MX Fuel Carry-On MXF002
  • ABB Thttps://bankofmanuals.com/view/1083495/abb-cap-505-operation-user-s-manual-36.html» target=»_blank»]bankofmanuals.com[/mask_link]

    Доброго времени суток, коллеги! Пришлось впервые столкнуться с REF543 и программой CAP 505 и тут же возникли всякого рода вопросы. Например, на бирке написано REF543KM127BAAA. Ведь, когда создаешь устройство, заходишь в его Object Properties, затем в Attributes появляется окно выбора аппаратного обеспечения. В раскрывающемся списке есть возможные его версии — например, REF543-1MRS118501.

    Как соотносятся то,что написано на бирке и то, что предлагает выбрать CAP 505, и где именно выбирается версия REF — С — control, B — basic, M — multi, а то из-за этого не получается закачать конфигурацию?

    2 Ответ от grsl 2012-02-09 19:57:53

    Re: Вопрос по CAP 505

    Ух коллега в формате форума будет сложновато пояснить.
    функциональность реле не выбирается, вы выбираете железо или 543 или 543R.

    Читайте также:
    Программа где можно музыку накладывать на музыку

    а после того строите конфигурацию .

    Вам надо построить конфигурацию с нуля или вам прислали конфигурационый файл?

    3 Ответ от Fpv 2012-02-09 20:05:36

    Re: Вопрос по CAP 505

    Конфигурацию мне дали, скачанную, помоему, с REF543GB127BAAA. И ее нужно закачать в новый — 543КМ127BAAA. Кстати, а что обозначает 543R, на заводском ГПП такой маркировки ни на одном устройстве не нашел, хотя конфигурации под такие REFы видел.

    4 Ответ от grsl 2012-02-09 20:10:38

    Re: Вопрос по CAP 505

    Означает что в реле есть карточка с аналоговыми входами 4-20мА, 0-5В. много вариантов.

    В каком виде дали конфигурацию: AR файл?

    5 Ответ от Fpv 2012-02-09 20:20:55

    Re: Вопрос по CAP 505

    Спасибо за ответ! Да, архив с расширением AR. Распаковал, как положено, соединение настроил, мимику закачивает, но проект и уставки качает с ошибками, а где все-таки задается версия С, B или M? Может где нибудь в Relay Configuration Tool? Как я понимаю в версии В отсутствуют функции защиты по напряжению и частоте, а мне нужно их добавить в своей версии М.

    6 Ответ от grsl 2012-02-09 20:26:40

    Re: Вопрос по CAP 505

    Всё верно, но какие ошибки, только при загрузке уставок?

    Так и должно быть, вам дали файл с старой версии реле, в новой есть дополнительные параметры и и потому иногда идёт ругачка.
    сделайые пожалуйста скриншоты выскакивающих ошибок и приложите на форуме.

    если у вас реле М, то просто в Relay Configuration Tool добавьте функции по напряжению и частоте, в библиотеке всегда присутствуют все функции, а М примет всё.

    7 Ответ от Fpv 2012-02-09 20:31:05

    Re: Вопрос по CAP 505

    А как правильно выбирается библиотека под данный тип? Там их несколько на REFы (REFLIB01, 02, 03, 04).

    8 Ответ от grsl 2012-02-09 20:36:47

    Re: Вопрос по CAP 505

    Чтобы заново не лопатить всю конфигурацию, делайте с тем что установлено, наверное 03, G старая версия.
    саму библиотеку не надо трогать она уже стоит, но для частоты надо будет создать таск в 5мс и проставить галочки в определениях аналоговых входов.

    Источник: rzia.ru

    ABB CAP 505 Manuals

    Documents: ABB CAP 505 Tools PDF User Manuals and Service Instructions (1 ABB CAP 505 Manuals found in DataBase)

    ABB CAP 505 Operation to 2″ x

    246/130-944E

    More Products:

    HP V6110US — Compaq Presario Media Center Operation User’s Manual

    GE DEH-210 Operation User’s Manual

    Agilent Technologies E1465A Operation https://pdfcs.com/device/abb/cap-505/» target=»_blank»]pdfcs.com[/mask_link]

  • Рейтинг
    ( Пока оценок нет )
    Загрузка ...
    EFT-Soft.ru